XPJ-1641SR-P2 v1.01
Necessary tools
In order to be able to install firmware, the following tools are required:
- Personal computer with MS Windows
- Network cable to connect the XpertJet with the pc
- The latest MSA-tool (Mutoh Service Assistance) or MSM-tool (Mutoh Status Monitor)
Detailed instructions how to install the firmware, are described in the maintenance manual.
The latest current firmware can be downloaded below this article.
Current version 1.01
** Make sure when updating to F/W Main Ver1.01 or higher to use MSA tool Ver.6.0.6 higher.
Bug fix:
- There was a problem in the print head temperature compensation table. After updating the firmware, the Bi-D readjustment is required in self-diagnostic mode.
- When the auto sleep timer automatically switches to the sleep mode, cleaning in a mode different from the setting for the cleaning operation during the sleep mode is performed.
- When switching to sleep mode, a error "E092: CR overload" may occur.
- When receiving data from VerteLith, if the panel displays "Receiving", and you cancel the data from VerteLith, the panel will remain in "Receiving" mode. If a cancellation is performed in this state, the panel will continue to display "Canceling".
- When performing continuous printing with VerteLith with media cut enabled, printing stops midway after printing a few sheets, or printing does not start.
Added:
-
If auto cleaning cannot be performed due to the cover being open or some other error, the print head nozzles may become clogged. To prevent a long period of time from passing without being able to perform maintenance operations such as auto cleaning, the printer will display an error message and beep to notify the user.
-
If a parameter other than the print mode that can be set is received with the "*PQ" command, printing with MPS will not be permitted and the printer will switch to a print method other than MPS.
Installed Ver 1.01 Serial number:
XPJ-1641SR-P2 : LB6U000071~
| Attachments (1) |
| XPJ1641SR-P2_V101.jfl 2.21 MB |