How to switch a XPJ-1641SR-P from UMS to MS41 or MS51 ink
IMPORTANT: we advise you to pro-actively replace the ink pump (DH-40598) on field-units in order to ensure a good ink switch. In case the pump is not working 100% anymore the ink switch might result in missing nozzles after the switch. Extra ink charges might be necessary then to get all nozzles active.
1. Required items:
• FW V1.04 (or higher).
• MSA 5.0.9.0.
• Spitting box inlay: part number IJ-FLABS-02.
• Wiper: part number IJ-RWPS-01.
• UMS11-CL300E cleaning packs (4 Pieces).
• MS41-CL300E cleaning packs (4 Pieces).
• MS41 or MS51 ink.
• New ink pump: part number DH-40598.
2. Procedure:
• Install the V1.04 (or higher) firmware. You can use MSA V5.0.9.0. or later.
• Power on the printer in User Mode.
• Perform a nozzle check (in User mode) to document the current status of the print head.
• Power down the printer.
• Replace the pump to ensure a good ink switch!
• Start the printer in Self-Diagnosis mode.
• Reset the pump life time counter (>parameter>init.counter>pump).
• Empty the waste bottle.
• Perform a 'Longstore' (>Adjustment>Longstore) using NEW UMS11 cleaning bags and NEW UMS11 smart chips.
• Follow the instruction on the panel: Insert cleaning - Remove bags - ...
• When the procedure is finished, the panel shows "LONGSTORE".
• Power down the printer.
• Replace the spitting box inlay to IJ-FLABS-02.
• Replace the wiper.
• Empty the waste bottle.
• Power on the printer in User Mode.
• Display shows: 'INK charge - Start>Enter' , then Press <Enter>.
• Insert NEW MS41 cleaning bags and NEW MS41 smart chips.
• After the washing cycle, the display will show: "Wash Retry?". Choose No.
• Perform an 'ink charge' using MS41 or MS51 ink bags.
• Recalibrate the BI-D of the printer.
• End of procedure.