In analogy with the inclined lamp type of the VJ-1638UR, the VJ-1638UH units will also be equipped with this type of lamp.


This revised set-up will be implemented as of serial number ID6U001001.


The previous VJ-1638UH lamp type, the DG-46905 is obsolete and is replaced by the same spare part as currently used on the VJ-1638UR, the DG-48687.


In order to be able to mount these lamps on a VJ-1638UH equipped with the first generation lamps, a new cursor and a corresponding bracket kit need to be installed.


Overview:


  1. In case you need to change the UV LED lamp on a VJ-1638UH with serial number ID6U001000 or earlier following actions need to be taken (one time only):
    • Update the VJ-1638UH Firmware to 1.09 or higher and set the lamp type to “lamp B”
    • Install the new cursor: DG-49367
    • Install the V50 corresponding kit: DG-49369 (includes brackets and 2x UV LED lamps)
      • Please see attached separate sheets:
        • “installing the UV lamp (V50) corresponding kit”
        • “UV lamp mounting position adjustment”
      • Tools needed to adjust the lamp:
        • DG-46924 (UV LED mounting height jig)
        • DG-49073 (UV lamp jig for slant adjustment)
        • DG-49074 (UV lamp jig for height adjustment)
      • Info: in case only the cursor needs to be replaced on such a unit (no lamps), then the existing model DG-49022 can still be ordered in limited quantities.

  2. In case you need to change the UV LED lamp on a VJ-1638UH with serial number ID6U001001 or later, or on a VJ-1638UH with older serial number but that has already been upgraded (see point 1):
    • Replace the lamp DG-48687

  3. In case “only the cursor” (no UV LED lamps) needs to be replaced on:
    • A VJ-1638UH with serial number ID6U001000 or earlier: The existing model DG-49022 can still be ordered in limited quantities.
    • A VJ-1638UH with serial number ID6U001001 or later, or on a VJ-1638UH with older serial number but that has already been upgraded earlier (see point 1): Use the new cursor type DG-49367.

  4. Periodical maintenance kit:

    As a result of this change in configuration of the VJ-1638UH also the definition of the “periodical maintenance kit” for VJ-1638UH was changed.
    • First kit number: DG-47766 (includes a fixed wiper) : no longer available
    • Second kit number: DG-49368 (includes a new replaceable wiper and set of UV lamp filters for the new lamps) : no longer available
    • Third kit number: DH-40870 (same as second type , without dampers)

  5. Spare UV-lamp filter set:

    In case the filters on these new lamps need to be replaced, then following part number is valid for a set of 2 filters: DG-48990 (same as for VJ-1638UR)


Article changes

Revision 1.0 : 24 october 2019 - Initial release
Revision 2.0 : 24 March 2022 - changed partnumber