Background of the change: 


If printing is cancelled from the printer while a job is in progress, the UV lamp may remain illuminated for about 6 seconds even though the carriage has stopped.

Error 215 is then triggered; and the UV lamp turns off after those 6 seconds.


This occurs when the print is cancelled under following conditions:

  • Uni-Dir printing
  • After printing, when the carriage is moving from left to right during additional UV curing.


 Both conditions must be met simultaneously.


Beware: 

During this 6 seconds period, certain media types may melt, as shown in the picture below:




Cause: 


A defect in the fail-safe program (Error 215/217) caused improper monitoring of the UV lamp status when the carriage was stopped.


Countermeasure: 


The Firmware has been corrected in version 1.06.

The UV lamp fail-safe logic has been fixed to prevent the lamp from remaining switched on unnecessarily.


Cut-in Serial numbers: 

  • XPJ-1682UR: KV6U000056 and later
  • XPJ-1682URE: KV6E000035 and later


Urgent Market Action: 


In order to avoid having safety issues please update the FW versions as soon as possible to these latest versions.

End-users can update the FW themselves by using the MSM software tool