XPJ-1462UF Main FW 1.10 ; MOT_LED Control FW 1.04

Modified on Mon, 8 Sep, 2025 at 3:11 PM

Necessary tools


In order to be able to install firmware, the following tools are required:

  • Personal computer with MS Windows
  • Network cable to connect the XpertJet wit the pc
  • The latest MSA-tool (Mutoh Service Assistance)


Detailed instructions how to install the firmware, are described in the maintenance manual.


The latest current firmware can be downloaded below this article.



Release date: 11 August 2025

Main FW v1.10


EXTRA INFO:


1/ Important: Please make sure to use the latest Vertelith Software version.

2/ Always please make sure to first update the MOT_LED Control FW and then the Main FW.


1:[Added] Add soak cleaning menu to user mode.

2:[Added] CR distance adjustment function
This function compensates for the expansion and contraction of the encoder scale due to environmental changes.
This function is enabled by printing with VerteLith.

3:[Added] Menu for display the remaining time until ink agiting and for executing agiting.
- When the ENTER key is pressed on the ""Ready Print"" screen, the remaining time until agitation of WH and KCMY inks is displayed as ""Until agitation"", and Ink agitating can also be performed immediately.

4:[Added] Using the printer in a temperature environment outside the guaranteed operating range may cause mechanical problems (the optical axis of the laser sensor may shift, reducing the accuracy of height detection) or physical problems (the ink may change quality or not curing).
To prevent and suppress such problems, a warning will be displayed on the main panel and on VerteLith and MSM if the printer temperature (temperature information for head 1) falls below 18C or exceeds 50C. If the printer temperature falls within the guaranteed operating range, these warnings will automatically disappear."

5:[Added] Before starting the ink circulation process, the solenoid valve will cycle on and off several times to prevent the solenoid valve from sticking.


6:[Fixed] During media setting processing, a "communication error" may occur on VerteLith.

7:[Fixed] If the initial charge is performed without turning off the power after longstore in self-diagnosis mode under the following conditions, the "ink type" recorded in the ink switching log will be recorded as "UH21 ink" regardless of the type of ink charged.
- "Ignore" or "Chip Trouble" is set in ACG.
- The ink type before head cleaning is "US61 ink".

8:[Fixed] If the printer stops at Ink end when starting up, the "Initializing" message remains, so it was impossible to tell that the ink end. The "No ink" error message will now be displayed.

9:[Fixed] Use VerteLith or MPS to send multiple print data at once.
If the ink cartridge agitation time occurs during printing, the current print will end normally but the next print may not start.

10:[Fixed] In the self-diagnosis mode, "Test > History > Print > PG", the number of printed pages was not saved in the history.

11:[Fixed] When "Chip Trouble" is set by ACG application, the ink type can be changed in the Self-diagnosis mode Parameter: Update: Ink type menu, but sometimes it is not possible to do so.

12:[Fixed] When Longstore is performed on a machine charged with "UH21 ink", the machine can be recharged with "UH21 ink", but cannot be recharged with "US61 ink".

13:[Fixed] When performing initial charging, if "UH21 ink" and "US61 ink" smart chips are inserted together, an ink error for the smart chip may not occur and initial charging may be performed.


14:[Changed] The threshold for temperature abnormality errors to prevent UV LED Temperature Error(E226/E230) from occurring frequently in low temperature environments.
The threshold at which the UV LED Temperature Error (E226/E230) occurs has been changed to around 0C to -19C.

15:[Changed] If the power was left on for 24 hours, backup parameters, including the "Printer Usage" log, were sometimes not recorded in memory. Backup parameters are now recorded in memory on a 24-hour cycle.


Installed Ver1.10 Serial number:
XPJ-1462UF : KQ5U000170~



MOT_LED Control FW v1.04:


1:[Changed] UV lamp temperature monitoring is performed only when the UV lamp is on.

2:[Fixed] When printing in an environment below -10C where a UV-LED Temperature Error occurs, "UV-* LED FAN* Rotation Error" may be displayed instead of "UV-* LED Temperature Error."



Installed Ver 1.06 Serial number: KQ5U000170 -




Release date: 16 January 2025

1.09


EXTRA INFO:


1/ Updating to F/W Main Ver1.07 requires MSA tool Ver.6.0.1 (or higher).

2/ Main FW1.06 requires MOT_LED version to 1.03 (or higher).

3/ Important: Please make sure to use the latest Vertelith Software version.

4/ Always please make sure to first update the MOT_LED Control FW and then the Main FW.


1:[Added] "Longstore" and "Ink Discharge" logs are now recorded.
The logs can be checked in self-diagnosis mode and with MSA 6.0.5 (to be released) or later.
-User mode:
Ink charge:"UC" on the panel, "Ink charge (User mode)" on the MSA Log list.
Longstore:"UW" on the panel, "Longstore (User mode)" on the MSA Log list.
- Self-diagnosis mode
Ink charge:"CH" on the panel, "Ink charge (Diagnosis)" on the MSA Log list.
      Longstore/Discharge:"LO" on the panel, "Longstore (Diagnosis)" on the MSA Log list.

2:[Added] If the power cable is suddenly unplugged, some parameters will not be saved in memory. Backup parameters will be saved every 24 hours.


3:[Added] There are plans to add a solenoid valve to the Wh channel to deal with uneven white ink density, so "Type C" is added to the Parameter->Update->Circulation in the self-diagnosis.
*Type A: No solenoid valve (Old circulation sequence - Same as up to Ver1.07 incl.)
*Type B: No solenoid valve (New circulation sequence - Added in Ver1.08)
*Type C: With solenoid valve


4:[Added] After tapping the direct key to display the cleaning confirmation screen, if no operation is performed for 3 minutes, the device will automatically return to the resident screen.

5:[Added] A new printing condition has been added to prevent stickiness when using US61 ink, which was added in the previous version(Ver1.08).


6:[Fixed] The backlight of the control panel keys may flicker momentarily while the setting screen is displayed.

7:[Fixed] The media set menu might appear before pressing the down arrow key to complete the media remove process.

8:[Fixed] Incorrect "Effect" processing was being performed under certain print conditions.

9:[Fixed] When the printer is charged with "US61" ink, if ink discharge and longstore are performed in self-diagnosis mode, the ink type will switch to UH21.

10:[Fixed] When a single-headed Longstore is executed, The saved ink type information on this head is switched to UH21, even if the loaded ink was US61.

 

Installed Ver1.09 Serial number: XPJ-1462UF : KQ5U000166~







Release date: 08 November 2024

1.08


EXTRA INFO:


1/ Updating to F/W Main Ver1.07 requires MSA tool Ver.6.0.1 (or higher).

2/ Main FW1.06 requires MOT_LED version to 1.03 (or higher).

3/ Important: Please make sure to use the latest Vertelith Software version.

4/ Always please make sure to first update the MOT_LED Control FW and then the Main FW.


1.[Fixed] E216 error occurs during UV lamp curing process using *US print manager command.

2.[Fixed] When changing the user type using the remote panel, the setting value displayed on the remote panel differs from that displayed on the printer panel.

3.[Fixed] Unintended character "P" is displayed on the panel in certain cases.

4.[Fixed] Even if the waste ink sensor reacts during "Ink discharge" in the self-diagnosis mode, the panel display does not change to "Full Waste Ink Tank".

5.[Fixed] When printing a pattern built into the printer, the user mode settings "MultiStrike" and "Pass wait" were enabled.
 The settings are now not reflected when printing a pattern built into the printer.

6.[Fixed] When a warning message is displayed, certain characters may be missing. This issue exists in French, Spanish and Portuguese.

7.[Fixed] If the display language setting is changed while a warning message is displayed on the main panel, unintended characters may be mixed in with the warning message immediately after the change.

8.[Fixed] "Self-diagnosis mode > adjustment > Feed pitch menu display content is wrong.
Wrong
Pitch: H/16 (2.117mm)
Pitch: H/16 (0.794mm)
Correct
Pitch: H/12 (2.117mm)
Pitch: H/32 (0.794mm)

9.[Fixed] When the smart chip terminal short circuit occurs due to the misalignment of the smart chip card attachment position on the ink cartridge, the chip recovery may not function and an I/C error may occur.
 Fixed chip recovery to work even in such cases.


10.[Fixed] If the ink bag was not shaken for a long time there was a possibility of uneven density (variation in density) in the white US61 ink.
 This was improved by reviewing the ink circulation process when coming out of sleep mode.

  • Less than 24 hours without agitation: added 2m30s
  • Between 24 and 72 hours without agitation: added 5m
  • More than 72 hours without agitation: added 7m30s

This new cycle can be activated by switching in self-diagnosis mode "Parameter/Update/Circulation" from Type A to Type B.


11.[Fixed] If the "Submit to Print" button is pressed on VerteLith when there is no media in the printer, and then the print is "cancelled" from the panel, the printer will freeze with the "Cancelling" message displayed.
 To recover, the printer must be restarted.

12.[Changed] If multiple sub-statuses (warning states) are registered in the printer, the display on the main unit panel will change at two-second intervals to display all sub-statuses.

13.[Changed] If the ink bag is removed without removing the large-capacity pack adapter while stirring the ink, the ink end detection flag will react and the ink is out flag will be set.
Only when the printer is in standby mode and not consuming ink, if the ink pack is removed, "Check ink" will be displayed to prompt the user to check the cartridge status

14.[Added] A function that displays the number of cleanings for each head in the maintenance history of the self-diagnosis mode.
* Before: Cleaning

* After: Cleaning1 / Cleaning2

15.[Added] When using US61 ink, the expiration date recorded on the ink S/C card is used as the basis, and if the expiration date is exceeded, the message "[**] Ink Expired" is displayed.
 Even if the ink expiration date has passed, the printer will simply display a message and you can continue printing.

16.[Added] Regardless of the type of ink, the message "Ink Not Expired?" will be displayed every 90 days starting from the ink charged date.
 The printer will simply display a message and you can continue printing.

17.[Added] The "PG Motor Control" menu has been added to the top menu of the self-diagnosis mode. This is a function for emergency control of the PG motor when the printer breaks down. If used for the wrong purpose, the printer may break down, so please handle with care.

18.[Added] The "PF Motor Control" menu has been added to the top menu of the self-diagnosis mode. This is a function for emergency control of the PF motor when the printer breaks down.

19.[Added] The following problems occur with US61 ink.
- The printed surface becomes sticky and sticks.
- The ink comes off when removing the stuck print.
 A new parameter for the UV irradiation method has been added to the printer manager command(*UC11/*UC12/*UC13).


Installed Ver1.08 Serial number:

XPJ-1462UF : KQ5U000166~

 

* Description: F/W MOT_LED_CONT Board Ver1.03

1:[Added] The MOT_LED_CONT board has been updated to Rev.E to prevents the issue where the UV lamp would not turn off even when the emergency stop button was pressed.
This firmware incorporates processing to control the Rev.E MOT_LED_CONT board. It can also control MOT_LED_CONT boards from revisions earlier than Rev.E.
 *If old controller firmware is installed on MOT_LED_CONT board Rev.E, the UV lamp will not work.

 

Installed Ver1.03 Serial number:
XPJ-1462UF : KQ5U000145~



Release date: 24 July 2024

1.07



Bug Fixes:


1:[Fixed] If the printer is left in the "Ready to Print" state for a long time, white ink may leak out of the machine.

==> Please check TIB 866


2:[Fixed] Errors "E215" to "E217" may occur.
This could occur when auto cap-in or cleaning was performed during printing.

3:[Fixed] "No S/C card" error in self-diagnosis mode is incorrect.
- Incorrect slot number is displayed.
- This error is not displayed during cleaning.

4:[Fixed] After setting the media, when printing was started with the suction fan temporarily stopped using the foot switch, printing started with the suction fan stopped.
Fixed in v1.04 was not enough, so it was fixed again.

5:[Fixed] The chip recovery function did not work when performing ink charge after ink discharged.

6:[Fixed] "Media setting>Set Media" may not work properly.
- When tapping the Enter key on the "Length **mm" input screen, the message "Cannot change during detection" may be displayed.
- When tapping the Enter key on the "Origin PF/CR" display, the printer may freeze with "Moving to OriginPosition" displayed.

7:[Fixed] During daily maintenance, the speed at which the carriage returned to the maintenance position was incorrect.
The difference in speed is so slight that it would be impossible to tell on the machine.

8:[Fixed] Problems with the display of "Printer status>Job status"
1. When checking "Job status/Status" after printing, "Canceled" is displayed.
2. After printing data that includes a blank feed, "Job status/ToDoLength" displays a distance that is shorter than the actual printed length.
3. After printing data that does not include "height" information, "Job status/ToDoLength" becomes "0.7m".
These problems do not affect the print history count.

9:[Fixed] Incorrect print area calculation.
1. The "data length" when calculating the print area was calculated to be approximately 22 mm too long.
2. The print area was not counted when the print data had no "height information" and the gantry moved in the opposite(back to front) direction during printing.
3. The data had no "height" information and a 10 mm margin was subtracted from the "data length," resulting in a smaller print area.
There is no significant impact on the total print area calculation.

10:[Fixed] When printing in Draft mode (360x1080dpi), the number of printed pages was counted as groups with different data widths.
This does not affect the total print count.

11:[Fixed] A CPU error occurs when connecting to a PC with antivirus software (AVG AntiVirus) installed.


Changes:

12:[Changed] The contents of the error log for E215 to E217, which were added in Ver1.04.

13:[Changed] When using the high capacity ink pack adapter, the "Check Ink" message appears even if there is sufficient ink remaining in the ink pack.
The threshold at which the "Check Ink" message appears has been changed to an appropriate value.

14:[Changed] The nozzle check L pattern was print twice to make it easier to see.

15:[Changed] When using US61 ink, the print quality is no good when the head gap is large, so this has been improved.

16:[Changed] The operation of daily maintenance and CR maintenance has been improved.
- The carriage movement speed was dangerously fast, so it has been slowed down.
- If the cover is not opened after daily maintenance is performed and 30 seconds is left unattended, only the CR will be moved to the home position, shortening the time it takes to rerun the maintenance.


Added:

17:[Added] A parameter for the "UV control" PM command to enable high-gloss printing.
By selecting a dedicated profile from VerteLith, the printing conditions required for high-gloss printing, including the above PM command, are automatically set.

18:[Added] "Curing operation (UV lamp irradiation)" is possible after printing.
It can be controlled with PM commands.



Installed Ver1.07 Serial number:
XPJ-1462UF : KQ5U000160~
XPJ-1462UF(A) : KQ5A001010~


 

Release date: 20 March 2024

1.06


==> Internal changes, not user related.


Installed Ver 1.06 Serial number: KQ5U000158 -



MOT_LED Control FW v1.03:


Add:

  • The MOT-LED Cont board has been updated to RevE. This revision was needed to avoid that the lamp would not switch OFF when the emergency button is pressed. Version 1.03 is needed to process correctly boards from RevE. It can also control MOT-LED boards fromolder revisions than E.

==> Please update the  MOT-LED CONT board FW to version 1.03.


*If old controller firmware is installed on MOT_LED_CONT board Rev.E, the UV lamp will not work. 


Installed Ver 1.06 Serial number: KQ5U000145 -

Release date: 20 March 2024

1.05


EXTRA INFO:


1/ Updating to F/W Main Ver1.05 requires MSA tool Ver.6.0.1 (or higher).

2/ Main FW1.05 requires MOT_LED version to 1.01 (or higher).

    However we advise to install the new MOT_LED version 1.02 in combination with 1.05.

3/ Important: Please make sure to use the latest Vertelith Software version.

4/ Always please make sure to first update the MOT_LKED Control FW and then the Main FW.



Bug Fix:

  • If ink was discharged from both heads, but head rank was entered for only one head, it could not be printed. 
  • When printing from VerteLith under the following conditions, printing stopped halfway through.
    1. Color mode:KCMY(4-plane)
    2. Printing direction:Reverse
  • After canceling the media set and performing CR maintenance, the carriage collided with the linear guide rail cover.
  • When printing the adjustment ALL in self-diagnostic mode with a short media length, printing stopped halfway through.


Add:

  • When setting the media, the media height is detected after the gantry is lowered to the origin position.
    Added "Confirm Media Height Change" menu.
    "Setup"->"User Type"->"Media Setting"->"Height:Auto"->"Confirm Height:Off/On".
    When "On" is selected, a "Confirm media height change" message is displayed after setting the media.
     When the media height is not changed, the media height is detected after the gantry is lowered to the media height position.
  • Added menu to check if the ionizer is working properly.
     "Maintenance"->"Ionizer"


Changes:

  • When US61 ink is used: Changed the sequence of flushing before printing starts.
  • Self-diagnosis mode: Changed to clean only the ink-discharged heads.
  • Self-diagnosis mode: Changed laser sensor adjustment menu (see TIB 862).
  • Changed to print "Media Thickness (PG Offset)" on the right edge of the UniD/BiD adjustment print pattern.
  • Changed to print "Media Thickness (PG Offset)" on the right edge of various adjustment print patterns.


Installed Ver 1.05 Serial number: KQ5U000122 









Release date: 19 December 2023

1.04

EXTRA INFO:


1/ Updating to F/W Main Ver1.03 requires MSA tool Ver.6.0.1 (or higher).

2/ Main FW1.04 requires MOT_LED version to 1.01 (or higher)

3/ Important: When installing XPJ-1462UF FW1.04, please also upgrade the Vertelith Software to V7.02 or higher.



Bug Fix:

  • If the "ink charge"-process is interrupted due to a cover open or an error, the ink charging process will be interrupted and the ink will be considered to have been filled, even if the ink has not reached the print head. So, if the process is interrupted during ink charge, suction will resume for the remaining time once the error is removed. It was fixed so that ink charging completes correctly.
  • If the ink in the ink adapter runs out during ink charging and the ink end pin is detected, the ink end was not detected. This is now fixed.
  • To avoid White nozzle missing during continuous printing, the conditions for spitting White ink at the start of the printing have been reviewed to improve nozzle stability.
  • Even though the S/C error log is recorded, no error is displayed on the self-diagnosis mode -> inspection -> history -> S/C log. This is now fixed.
  • After setting the media, when printing was started with the suction fan temporarily stopped using the foot switch, the printing started with the suction fan stopped.
  • If printing is interrupted by the cancel key on the operation panel towards the end of printing, the machine may hang with "Cancelling" displayed. This is now fixed.


Add:

  • When repairing a machine, it is necessary to cap out the carriage. However, if an error occurs during the initial sequence, it cannot be capped out.
     The cap-out function in self diagnosis mode has been changed to work without an initial action.
  • If ink is left in the waste ink bottle for a long time, components of the ink may settle and the waste ink may not be able to be discharged. A message has been added to drain the ink every 7 days even if the waste ink tank is not full.
  • The "UC" (UV control) command of the PM command has been improved.
     "-3 to -5 (weakens the UV lamp illuminance)" has been added to the options for the second parameter of the *UC command.
  • When the following error occurs, the printer status is saved to provide hints for investigating the cause.
    -"E215(UV SafeCtrl1)"
    -"E216(UV SafeCtrl2)"
    -"E217(UV SafeCtrl3)"


Changes:

  • When the left arrow key on the panel was pressed from the Ready to print state, one type of nozzle check was printed.
     Changed so that you can select between nozzle check and nozzle check B.
  • When the ink status "[**] Check color" message was displayed, the status LED on the panel was lit green. However,      "[**] Check color" is an error state. Therefore, it has been changed to a red status LED.
  • Even though the S/C card LED was blinking (near end), the message "Ink Low" was not displayed on the panel.
     The message "Ink Low" is now displayed on the panel when the S/C card LED blinks (near end).
  • Print quality may deteriorate if the material has an uneven surface.
    Added the ability to print at 50% carriage speed to improve image quality.
    Note:
    When this function is set, the printing direction is fixed to uni-direction.
    This function is setting through the panel menu, MSM, and Print Manager commands(*CV).
  • In the Self-diagnosis mode ==> Adjustment ==> Uni/Bi Low ==>BiD xxx VSDx ==>Print2/Print3 , the adjustment pattern has been changed.
  • The ink charging process in self-diagnosis mode has been changed to the same process as in user mode.
  • If the obstacle sensor reacts during daily maintenance, the daily maintenance process was interrupted.
    If the obstacle sensor reacts during daily maintenance, a message to confirm the obstacle will be displayed, and you can continue the work by pressing the Enter key.
  • A head height adjustment menu has been added to the mechanical adjustment menu to check and adjust the head height.
  • The operation process of laser adjustment in self-diagnosis mode has been changed.
     The process has returned to the same routine as in Ver1.00.
  • Some messages during the initial filling process have been changed: "Longstore" ==>"WashPrintHead"
  • The print result of [Print -> Error History] in self-diagnosis mode has been adjusted to fit within A3 size.
  • If an obstacle was detected during printing and the print was canceled when capping in, a "Media height Error" was displayed. Cancellations and errors are now displayed separately.
  • The lifetime of the dustproof cover was controlled using one parameter for four dustproof covers.
     Changed to manage 4 locations individually.
  • The error judgment margin for E215 (UV SafeCtrl1) added in Ver1.03 was small.
     The error judgment margin has been changed.
  • If an unexpected value is set during the obstacle sensor-adjustment in self-diagnosis mode, the procedure has been changed to readjust it.


Installed Ver 1.04 Serial number: KQ5U000071

Release date: 07 November 2023

1.03

EXTRA INFO:


1/ Updating to F/W Main Ver1.03 requires MSA tool Ver.6.0.1 (or higher).

2/ Please first update the MOT_LED version to 1.01 (this can be done via the MSA tool). 


Bug Fix:

  • Fixed freezing and abnormal ejection during printing (by reviewing the printer's internal memory allocation)
  • Processing of the E217 error has been fixed (E217 = error related to the UV safety control)


Add:

  • Emergency mode E096 error (if the memory allocation is incorrect E096 will be displayed). This measure will prevent the printer from getting into a "freezing" state by placing it in a "system error" state.




Release date: 25 September 2023

1.01





EXTRA INFO:


1/ Updating to F/W Main Ver1.01 (or higher) requires MSA tool Ver.6.0.0 higher.

2/ Please first updat the MOT_LED version to 1.00 (this can be done via the MSA tool). When not done the printer will fail to upgrade to 1.01.




Installed Ver 1.01 Serial number: KQ5U000027
 