Necessary tools
In order to be able to install firmware, the following tools are required:
- Personal computer with MS Windows
- Network cable to connect the XpertJet wit the pc
- The latest MSA-tool (Mutoh Service Assistance)
Detailed instructions how to install the heater firmware, are described in the maintenance manual.
The latest current heater firmware can be downloaded below this article.
Release date 14 August 2024
Ver 7.03
Support for new model XPD-924D
Installed Ver 7.03 Serial number:
HA-1642 KR6U000009~
XPJ-1682SR-P KK6U001196~, KK6U301060~
XPJ-1682SR-PK KL6C000179~
XPJ-1641SR-P KF6U001590~
XPJ-1341SR-P KD5U000933~
XPJ-1682D KM6D000151~
XPJ-1642WR JX6U000761~
Version history
Ver 7.02
New support for HA-1642
Installed Ver 7.02 Serial number:
HA-1642 KR6U000001~
XPJ-1682SR-P KK6U001147~, KK6U301060~
XPJ-1682SR-PK KL6C000179~
XPJ-1641SR-P KF6U001555~
XPJ-1341SR-P KD5U000921~
XPJ-1682D KM6D000151~
XPJ-1642WR JX6U000761~
Ver 7.01
New support for XPJ-1341SR-P
Installed Ver 7.01 Serial number:
XPJ-1682SR-P KK6U000001~
XPJ-1641SR-P KF6U000001~
XPJ-1341SR-P KD5U000001~
XPJ-1641SR JF6U002714~
XPJ-1682SR JN6U001621~
XPJ-1642WR JX6U000141~
Ver 7.00
Changes
- No changes in functionality or performance in version 7.0, only the hardware is different due to changed hardware components. Make sure to use the correct version with the correct compatible board identification
| DG-49562 - Heater Control Board Assy | DH-40578 - Heater Control Board Assy |
![]() | ![]() |
| PCB identification tag GTV****** | PCB identification tag GUJ****** |
This heater board (with firmware v6.00) is used on the following serial numbers
| This heater board (for use with firmware v7.00) is used on the following serial numbers
|
| Compatible with heater FW file extension *.mfl | Compatible with heater FW file extension *.hfl |
| Usable with heater FW version 6.00 only! | Usable with heater FW version 7.00 or higher |
Important info
- The latest mainboard firmware on XpjertJet SR/WR series (2.00 or higher) is required
- The MSA tool detects the heater board type automatically, so mixing up F/W versions is impossible. When older type heater board is installed in the printer MSA tool allows you only to load F/W file with .mfl extension. When newer type heater board is installed in the printer MSA tool allows you only to load F/W file with .hfl extension
- If this heater firmware is used with older mainboard firmware versions, the heater might become out of control without any error message
- The heater firmware can only be installed with MSA 5.0.7.0 or higher.
Was this article helpful?
That’s Great!
Thank you for your feedback
Sorry! We couldn't be helpful
Thank you for your feedback
Feedback sent
We appreciate your effort and will try to fix the article