In order to be able to install firmware, the following tools are required:
- Personal computer with MS Windows
- Network cable to connect the XpertJet wit the pc
- The latest MSA-tool (Mutoh Service Assistance)
Detailed instructions how to install the firmware, are described in the maintenance manual.
The latest current firmware can be downloaded below this article.
Release date: 19 November 2025
Main FW 1.06 / LED Controller V1.03
** Make sure when updating to F/W Main Ver1.06 and LED_cont Ver1.03 to use MSA tool Ver.6.0.6 or higher.
LED Controller V1.03:
==> This LED controller FW is released in combination with Main FW1.06
1:[Fixed] When a UV lamp system error occurs during printing, the UV lamp may remain lit for approximately three seconds before the printer automatically restarts, even though it should immediately turn off.
Main FW 1.06
1.[Fixed] UV lamp does not turn off when job is canceled. (Fail-safe issue)
2.[Fixed] When a UV lamp system error occurs, it takes a long time for the printer to restart. (Fail-safe issue)
3.[Fixed] There was a flaw in the method for determining whether the UV lamp was on or off. (Fail-safe issue)
4.[Fixed] UV lamp life time counter not recorded.
5.[Fixed] When printing data created with Fiery's RIP, missing dots and misaligned printing of specific colors occur.
6.[Fixed] The circulation pump is driven during regular ink circulation, but the circulation pump's life counter is not updated correctly. It is counting at 1/20 of the actual life.
7.[Fixed] Even if the printer is left idle for several minutes, it may not enter a power saving mode (where the vacuum fan and ventilation fan are turned off). 8.[Fixed] When "Temperature too low" is displayed on the control panel, if "either" of the two heads reaches the specified temperature, the "Temperature warning" display will disappear. This is not correct processing, and the "Temperature too low" display should be disappeared when "both" of the two heads reach the specified temperature.
Installed Ver 1.06 and Ver 1.03 Serial number:
XPJ-1682UR : KV6U000056~
XPJ-1682UR(E) : KV6E000035~
Release date: 28 March 2025
Main FW 1.05 / LED Controller V1.02
EXTRA INFO:
1/ Updating to F/W Main Ver1.00 (or higher) requires MSA tool Ver.6.0.3 (or higher).
2/ Important: Please make sure to use the latest Vertelith Software version.
LED Controller V1.01:
==> This LED controller FW is released in combination with Main FW1.05
1:[Fixed] When printing in an environment below -10C where a UV-LED Temperature Error occurs, "UV-* LED FAN* Rotation Error" may be displayed instead of "UV-* LED Temperature Error."
Installed Ver 1.02 Serial number:
XPJ-1682UR : KV6U000063~
XPJ-1682UR(E) : KV6E000041~
Main FW 1.05
1:[Fixed] When using US61 ink and performing two-layer printing (white overlay, etc.), if printing is canceled during printing, the printer will freeze.
2:[Fixed] When entering and waking up from sleep mode, a "communication error" may occur on VerteLith.
3:[Fixed] When sending print data that includes a command to switch the User Type from VerteLith or MPS, printing is performed without switching "Media Thickness (um)".
4:[Fixed] Ink information was not updated correctly when ACG was set to Ignore.
5:[Added] Before starting the ink circulation process, turn the solenoid valve on and off several times to prevent it from sticking and ensure that the solenoid valve works normally when the ink circulates.
6:[Added] Using the printer in a temperature environment outside the guaranteed operating range may cause mechanical problems or physical problems (the ink may change quality or not curing).
To prevent and suppress such problems, a warning will be displayed on the main panel and on VerteLith and MSM if the printer temperature (temperature information for head 1) falls below 18C or exceeds 50C. If the printer temperature falls within the guaranteed operating range, these warnings will automatically disappear.
7:[Added] Added US81 as supported Ink type. (pre-installed as of KV6E000033, KV6U000049)
Installed Ver 1.05 Serial number:
XPJ-1682UR : KV6U000063~
XPJ-1682UR(E) : KV6E000041~
Release date: 28 March 2025
Main FW 1.03 / LED Controller V1.01
EXTRA INFO:
1/ Updating to F/W Main Ver1.03 requires MSA tool Ver.6.0.3 (or higher).
2/ Important: Please make sure to use the latest Vertelith Software version.
LED Controller V1.01:
==> This LED controller FW is released in combination with Main FW1.03
[Changed] The threshold for temperature abnormality errors to prevent UV LED Temperature Error(E226/E230) from occurring frequently in low temperature environments.
The temperature measurement range of the UV lamp will change from "0C ~ +80C" to "-20C ~ +90C".
Installed Ver 1.01 Serial number:
XPJ-1682UR : KV6U000045~
XPJ-1682UR(E) : KV6E000033~
Main FW 1.03
1:[Fixed] If the printer stops due to an Ink end when starting up, the "Initializing" message remains, so it was impossible to knwo the ink was empty. The "No ink" error message will now be displayed.
2:[Changed] If the power was left on for 24 hours, backup parameters, including the "Printer Usage" log, were sometimes not recorded in memory. Backup parameters are now recorded in memory on a 24-hour cycle.
3:[Changed] The threshold for temperature abnormality errors to prevent UV LED Temperature Error(E226/E230) from occurring frequently in low temperature environments.
The threshold at which the UV LED Temperature Error (E226/E230) occurs has been changed to around 0C to -19C.
4:[Changed] If the time to agitate the ink comes during printing, the message "Agitate ** ink" was displayed, and there was a risk that the ink cartridge would be removed during printing. The message will change to "Ink-agitate after printing".
5:[Changed] If the message "Agitate ** ink" is displayed, auto cleaning will not be performed.
6:[Added] A parameter has been added to the PM command to improve gloss printing.
7:[Added] During nighttime operation or continuous printing, "Agitate ** Ink" may be displayed and printing may stop.
A settings menu has been added so that online printing can be performed even when "Agitate ** Ink" is displayed.
"Print stop" has been added to "Ink agitation3". If you change it to "Off", printing will continue even if "Agitate ** Ink" is displayed.
Please note that there is a risk of print defects if printing continues without agitation.
Installed Ver 1.03 Serial number:
XPJ-1682UR : KV6U000045~
XPJ-1682UR(E) : KV6E000033~
Release date: 15 January 2025
1.02
EXTRA INFO:
1/ Updating to F/W Main Ver1.02 requires MSA tool Ver.6.0.3 (or higher).
2/ Important: Please make sure to use the latest Vertelith Software version.
1:[Fixed] Depending on the placement of print objects, an E215 error may occur.
2:[Fixed] If there is white space within a print object, the media will backfeed in that area, making the white space smaller.
3:[Fixed] The backlight of the control panel keys may flicker momentarily while the setting screen is displayed.
4:[Fixed] US61 ink expiration date information may not be recorded in the log.
5:[Fixed] In Setup > Advanced Settings > Origin, after the CR has moved to the origin position, open the cover while "Confirm Position End -> Enter" is displayed. The panel display will change to "Cover Open", but after 5 seconds all displays on the panel will disappear.
6:[Fixed] When an ink-related error occurs, the "soak cleaning" process starts, and the panel becomes inoperable during the process.
7:[Fixed] When continuously printing using VerteLith or MPS, the printer may display "Receiving" and not start printing.
8:[Added] "Longstore" and "Ink Discharge" logs are now recorded.
The logs can be checked in self-diagnosis mode and with MSA 6.0.5(Not yet released) or later.
-User mode:
Ink charge:"UC" on the panel, "Ink charge (User mode)" on the MSA Log list
Longstore:"UW" on the panel, "Longstore (User mode)" on the MSA Log list
-Self-diagnosis mode
Ink charge:"CH" on the panel, "Ink charge (Diagnosis)" on the MSA Log list
Longstore/Discharge:"LO" on the panel, "Longstore (Diagnosis)" on the MSA Log list
9:[Added] Menu for display the remaining time until ink agiting and for executing agiting.
- When the ENTER key is pressed on the "Ready Print" screen, the remaining time until agitation of WH and KCMY inks is displayed as "Until agitation".
- "Ink agitation" has been added to "Menu 8," allowing you to agitate inks immediately.
10:[Added] There are plans to add a solenoid valve to the Wh channel to deal with uneven white ink density, so a switching menu will be added to Parameter->Update->Circulation in the self-diagnosis.
*Type B: No solenoid valve (New circulation sequence - Added in Ver1.01)
*Type C: With solenoid valve
11:[Added] Waste Ink Tank Full log is recorded. The log can be checked on the MSA(from V6.0.5).
12:[Changed] Measures to reduce "Ink Low" caused by incorrect operation
When the printer is in standby mode and ink is not being consumed, if an ink pack is removed, "[**]Check Ink" will be displayed, prompting the operator to check the cartridge status.
Installed Ver 1.02 Serial number: XPJ-1682UR : KV6U000045~
Release date: 15 November 2024
1.01
EXTRA INFO:
1/ Updating to F/W Main Ver1.01 requires MSA tool Ver.6.0.3 (or higher).
2/ Important: Please make sure to use the latest Vertelith Software version.
1.[Added] The following problems occur with US61 ink.
- The printed surface becomes sticky and sticks.
- The ink comes off when removing the stuck print.
A new parameter for the UV irradiation method has been added to the print manager command.
2.[Fixed] If the ink bag was not shaken for a long time there was a possibility of uneven density (variation in density) in the white US61 ink.
This was improved by reviewing the ink circulation process when coming out of sleep mode.
- Less than 24 hours without agitation: added 2m30s
- Between 24 and 72 hours without agitation: added 5m
- More than 72 hours without agitation: added 7m30s
This new cycle can be activated by switching in self-diagnosis mode "Parameter/Update/Circulation" from Type A to Type B.
Installed Ver 1.00 Serial number:
XPJ-1682UR : KV6U000029~
Release date: 13 September 2024
1.00
EXTRA INFO:
1/ Updating to F/W Main Ver1.01 requires MSA tool Ver.6.0.3 (or higher).
2/ Important: Please make sure to use the latest Vertelith Software version.
First FW release for XPJ-1682UR
Installed Ver 1.00 Serial number:
XPJ-1682UR : KV6U000001~KV6U000028